{"title":"Doncaster Cables","description":"\u003cp\u003eDoncaster Cables EV-Ultra is a UK-made cable range built for electric vehicle charge point installations. The EV-Ultra Cat5e cable combines power conductors and a foil-screened Cat5e data cable in one double-sheathed run, so the installer feeds the charger and gives it a hard-wired data connection with a single cable instead of two.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/cable\"\u003eAll Cable\u003c\/a\u003e \/ \u003ca href=\"\/collections\/installer-equipment\"\u003eInstaller Equipment\u003c\/a\u003e \/ \u003ca href=\"\/collections\/consumer-units\"\u003eEV Consumer Units\u003c\/a\u003e \/ \u003ca href=\"\/collections\/ev-installation-kit\"\u003eEV Installation Kits\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eCan power and data run in the same cable?\u003c\/h3\u003e\n\u003cp\u003eIn EV-Ultra, yes. BS 7671 Regulation 528.1 generally keeps Band I (data) and Band II (230V power) circuits out of the same wiring system, unless every cable or conductor is insulated for the highest voltage present. EV-Ultra's power and data conductors are rated to the same nominal voltage, which meets that condition, so separate segregation is not required. The data pairs are screened and twisted, and Doncaster recommends terminating the screen to earth.\u003c\/p\u003e\n\u003ch3\u003eWhy hard-wire a charger's data connection?\u003c\/h3\u003e\n\u003cp\u003eA wired connection gives the charge point a data link that does not depend on the strength of a Wi-Fi signal at the charger position, and can also carry an energy monitoring connection. Running it inside the supply cable means one run to route through walls and buildings, for a quicker and neater installation.\u003c\/p\u003e\n\u003ch3\u003eWhere can EV-Ultra cable be installed?\u003c\/h3\u003e\n\u003cp\u003eIt is designed for installation in air, clipped to a surface, on cable tray or ladder work and embedded in concrete. It can be laid direct in the ground where suitable mechanical protection is in place. The operating temperature range is -15°C to 90°C.\u003c\/p\u003e\n\u003ch3\u003eHow is the cable sold?\u003c\/h3\u003e\n\u003cp\u003eBy the metre. Set the quantity to the number of metres your run needs. Sizing for any job depends on the charger's current, run length, installation method and grouping, and must be confirmed by the installing electrician against BS 7671.\u003c\/p\u003e","products":[{"product_id":"doncaster-cables-ev-ultra3c6-0cat5-ev-cable-6mm-3-core-power-cat5e-data-per-metre","title":"Doncaster Cables EV-ULTRA3C6.0CAT5 EV Cable – 6mm² 3 Core Power + Cat5e Data – Per Metre","description":"\u003cp\u003eThe Doncaster Cables EV-ULTRA3C6.0CAT5 is a UK-made supply cable for electric vehicle charge points that combines three 6.0mm² copper power conductors with a foil-screened Cat5e data cable in one double-sheathed run. It feeds the charger and gives it a hard-wired data connection with a single cable, rather than two separate runs.\u003c\/p\u003e\n\u003cp\u003eSold by the metre: set the quantity to the number of metres your run needs.\u003c\/p\u003e\n\u003cp\u003eRunning power and data together is the point of this cable. The power and data conductors are rated to the same nominal voltage, which is the condition in BS 7671 Regulation 528.1 that allows them to share one wiring system. The data element uses screened twisted pairs laid to reduce interference, and Doncaster recommends terminating the screen to earth.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Data in One Cable\u003c\/strong\u003e – Three 6.0mm² power cores and a Cat5e FTP data cable in a single run, so the charge point gets a wired connection without a second cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFoil-Screened Cat5e\u003c\/strong\u003e – Four twisted pairs with a foil screen for a hard-wired data link to the charger or an energy monitoring device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e58A Maximum Current Rating\u003c\/strong\u003e – 6.0mm² plain annealed copper Class 2 stranded conductors (7\/1.04mm) to BS EN 60228, with a voltage drop of 7.9mV\/A\/m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDouble-Sheathed Construction\u003c\/strong\u003e – XLPE Type GP8 insulation to BS 7655-1.3, PVC bedding and a Tuff heat-resisting PVC outer sheath for extra protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Installation\u003c\/strong\u003e – Suitable for installing in air, clipped to a surface, on cable tray or ladder, and embedded in concrete. It can be laid direct in the ground where suitable mechanical protection is in place.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWide Temperature Range\u003c\/strong\u003e – Rated from -15°C to 90°C operating temperature, with a minimum bending radius of 8 x overall diameter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuicker, Neater Installs\u003c\/strong\u003e – One cable to store, handle and route through walls and buildings, for a cleaner finished installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMade in the UK\u003c\/strong\u003e – Manufactured in Britain by Doncaster Cables.\u003c\/p\u003e","brand":"Doncaster Cables","offers":[{"title":"Default Title","offer_id":64711761002873,"sku":"EV-ULTRA3C6.0CAT5","price":9.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/9127\/9481\/files\/Cable.png?v=1790455423"}],"url":"https:\/\/www.echargersuk.co.uk\/collections\/doncaster-cables.oembed","provider":"eChargers UK","version":"1.0","type":"link"}